Analysis and Improvement of Damage to a 1200-Amper Rectifier Causing Current Surges During the Anodizing Process

dc.contributor.advisorWivanius Nadhrah
dc.contributor.authorLuthfi Lumazaqi, Karona
dc.date.accessioned2026-09-22T05:24:00Z
dc.date.issued2026-07-01
dc.description.abstractStudy this aim for analyze reason occurrence surge current in the rectifier system in the production process as well as evaluate effectiveness action improvements made for increase stability system. The method used is approach analysis cause and effect using a fishbone diagram that identifies four factor main reason disturbance, namely factor environment, factors operational factors machines, and factors human. Research results show that instability current caused by temperature high environmental conditions, less than optimal ventilation, use of system in a way continuously, and existence damage to components critical like capacitor in the circuit rectifier, IGBT, and module rectifier control, accompanied by weakness implementation maintenance periodically. After it is done improvement actions in the form of replacement damaged components, optimization system cooling, increase ventilation of the work area, as well as implementation of preventive maintenance and inspection periodically, occurs improvement performance significant rectifier system. Research results show level stability current increase up to ±85%, marked with decrease surge current in a way drastically and achieving greater output stable, so that system become more reliable and supportive smooth production process. Keywords: Rectifier, Current Surge, Anodizing, Fishbone Diagram, Preventive Maintenance.
dc.identifier.citationIEEE
dc.identifier.kodeprodiKODEPRODI20406#Teknik Elektronika Manufaktur
dc.identifier.nidnNIDN0019078903
dc.identifier.nimNIM3222301053
dc.identifier.urihttps://repository.polibatam.ac.id//handle/PL29/6896
dc.language.isoen
dc.publisherPoliteknik Negeri Batam
dc.subjectKeywords: Rectifier
dc.subjectCurrent Surge
dc.subjectAnodizing
dc.subjectFishbone Diagram
dc.subjectPreventive Maintenance.
dc.titleAnalysis and Improvement of Damage to a 1200-Amper Rectifier Causing Current Surges During the Anodizing Process
dc.typeArticle

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
3222301053_Artikel.pdf
Size:
679.24 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Borang_Publikasi.pdf
Size:
230.89 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Lembar_pengesahan.pdf
Size:
139.69 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: