2Viewes
Improvement of conveyor using motor inverter as automatic overload shutdown
Repository Analytics
Statistic Details
0Downloaded
2Accessed per month
2Countries
Loading...
Date
Authors
Ansyah, Yudi
Journal Title
Journal ISSN
Volume Title
Publisher
Politeknik Negeri Batam
Abstract
Conveyor systems in industrial manufacturing often
face overloading, causing motor damage and high downtime. This
study improves conveyor reliability at PT Sumitomo Wiring
System Batam Indonesia by implementing a motor inverter for
automatic overload shutdown. The system integrates the inverter
with an overload protection relay and an emergency stop.
Comparative results between the Delica Floor Lane (without
inverter) and Delica Inpanel Lane (with inverter) show that the
inverter reduced overload incidents from 18 to 6 and cut total
downtime duration from 420 to 75 minutes. Additionally, average
recovery time decreased from 30 to 15 minutes, while protection
effectiveness reached 94%. This optimization boosted production
output by 700 sets. Furthermore, Failure Mode and Effects
Analysis (FMEA) showed that a daily inspection check sheet
lowered the highest Risk Priority Number (RPN) from 378 to 108,
proving highly effective in preventing unplanned maintenance.
Description
Keywords
Citation
JAEE