Analisis Hubungan Daya Reaktif terhadap Variasi Pembebanan pada Generator Unit 4 PLTU PT Bintan Alumina Indonesia Berdasarkan Data Operasional SCADA

dc.contributor.advisorAtabiq, Fauzun
dc.contributor.authorPutri, Risky
dc.date.accessioned2026-08-31T07:09:12Z
dc.date.issued2026-07-06
dc.descriptionArtikel ini membahas karakterisasi operasional hubungan daya reaktif terhadap parameter daya aktif (P), daya reaktif (Q), tegangan (V), arus (I), frekuensi (f), faktor daya (PF), dan arus eksitasi. Data tersebut kemudian diolah melalui perhitungan parameter kelistrikan serta divisualisasikan dalam bentuk scatter plot untuk mengamati hubungan antar variabel pada Generator Unit 4 PLTU PT Bintan Alumina Indonesia berbasis data SCADA.
dc.description.abstractGenerators play a vital role in maintaining power system stability, particularly in regulating reactive power and power factor under varying load conditions. Variations in electrical load can affect the balance of active and reactive power generated by a generator. This study aims to analyze the relationship between reactive power and load variations in Generator Unit 4 at the PT Bintan Alumina Indonesia Coal-Fired Power Plant (PLTU) based on operational data obtained from the Supervisory Control and Data Acquisition (SCADA) system. A quantitative research method was employed by analyzing 30 days of generator operational data recorded at 1-hour intervals. The analyzed parameters included active power (P), reactive power (Q), voltage (V), current (I), frequency (f), power factor (PF), and excitation current. The data were processed through electrical parameter calculations and visualized using scatter plots to examine the relationships among the variables. The results indicate that excitation current has the strongest correlation with the reactive power of Generator Unit 4, with a correlation coefficient of r = 0,9062 and a coefficient of determination of R² = 0,8212. Excitation current regulates the magnitude of reactive power, which is subsequently associated with changes in power factor and voltage drop (ΔV). Furthermore, the relationship between active power and reactive power is positive but weak (r = 0,3593; R² = 0,1291), indicating that variations in reactive power are influenced more strongly by excitation current regulation than by changes in generator loading.
dc.identifier.citationIEEE
dc.identifier.kodeprodiKODEPRODI21309#Teknologi Rekayasa Pembangkit Energi
dc.identifier.nidnNIDN0018098305
dc.identifier.nimNIM4232201043
dc.identifier.urihttps://repository.polibatam.ac.id//handle/PL29/6717
dc.language.isoother
dc.publisherPoliteknik Negeri Batam
dc.subjectReactive Power
dc.subjectExcitation Current
dc.subjectGenerator
dc.subjectSCADA
dc.subjectPower System
dc.titleAnalisis Hubungan Daya Reaktif terhadap Variasi Pembebanan pada Generator Unit 4 PLTU PT Bintan Alumina Indonesia Berdasarkan Data Operasional SCADA
dc.typeBook

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
Borang_Publikasi .pdf
Size:
334.54 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Lembar Pengesahan .pdf
Size:
428.48 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
4232201043_TUGAS AKHIR .pdf
Size:
2.07 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: